Radiometer logo

AQT90 FLEX immunoassay analyser

Point-of-care biomarker testing made simple
Check with your local representative for availability in specific markets

  • Request info
    I would like to know more about the AQT90 FLEX Analyzer

    Contact Info

    Workplace Details

    By submitting this form, I acknowledge that I have reviewed and understood the data privacy notice.

    All fields must be filled!

  • Download brochure
    Sign up for downloading the AQT90 FLEX brochure
    Contact Info

    By submitting this form, I acknowledge that I have reviewed and understood the data privacy notice.

    All fields must be filled!

  • Accelerate patient flow
  • Make critical decisions fast
  • Ensure reliable results

Accelerate patient flow with point-of-care testing

Point-of-care testing (POCT) provides a significant reduction in turnaround times [1], has the potential to improve patient care, workflow efficiency [2], and mitigate overcrowding in the emergency department [3].

With the AQT90 FLEX analyser’s closed tube system, ease of use at point of care is taken to the next level.

Automatic pipetting and automatic patient ID look-up mean minimal handling—simply Drop‘n’Go.

  • Simply insert the collection tube into the AQT90 FLEX analyser

  • Get your test results delivered directly through the HIS/LIS system to the medical records
Product image of the AQT90 FLEX analyzer from Radiometer
 
 

5. Test cartridges inlet


  • Up to 240 tests when fully loaded
  • 24 hrs. onboard stability for CAL cartridge
  • Inventory alert when test number is low
 

3. Drop ’n’ Go


  • Directly insert the closed sample tube
  • Automatic pipetting
  • Automatic mixing
  • Test on both whole blood and plasma specimens*
  • Multiple tube types: EDTA, Heparin & Citrate**
  • Multiple tests can be run simultaneously.

  • *For the D-dimer assay, only whole blood samples can be used
    **Citrate only applies for the D-dimer test
 

6. Connectivity


  • HIS/LIS connectivity including automatic ‘patient ID lookup’
  • Complete data capture through continous synchronization and data sent through HIS/LIS to the medical records
  • Monitor analyzers, manage operators and quality controls across multiple sites
 

7. Barcode Reader


  • No manual data entry needed
  • Automatic reading of test cartridges
 

1. Customizable user interface


  • Adjustable touch screen
  • Onboard tutorials
  • Customizable test selection
  • Traffic light indicating current status
 

2. Quality Control (QC) Systems

Build in QC system automatical performs:


  • Environmental checks
  • Process checks
  • Preanalytical checks

Ready-to-use liquid quality control (LQC) tubes

 

4. Solution Pack ‘Closed System’


  • One solution pack for all tests
  • Collection of waste
  • Can be stored at room temperature
  • Monitors the number of tests used
  • Up to 200 tests before replacement is needed
  • Disposal of the whole pack to avoid contact with blood

 

Accelerate patient flow with the AQT90 FLEX analyzer

 





Make critical decisions fast

The AQT90 FLEX analyser delivers reliable results with a fast turnaround time. It has the capability to run up to 5 different tests per blood sample. Supporting you in making timely diagnosis of - or ruling out - several acute conditions.

You get results in 11-21 minutes based on the biomarker you’re testing. The immunoassay analyser allows you to initiate up to 30 tests per hour—you can manage more patients at the same time.

The AQT90 FLEX analyser covers an extensive range of critical biomarkers at POC.

Read more about the extensive range of biomarkers which aid in the diagnosis of:

Heart failure: 
NT-proBNP

NT-proBNP is an aid in the diagnosis of acute heart failure.

Read more

Myocardial infarction: 
TnI

The troponin I test is a cardiac biomarker for fast triage of patients with chest pain.

Read more

, CKMB

Creatine kinase-muscle/brain

Not available in the US

, Myo

Myoglobin

Not available in the US

Venous thromboembolism: 
D-dimer

D-dimer is a coagulation marker used as an aid in the diagnosis of venous thromboembolism (VTE).

Read more

Infection: 
PCT

Procalcitonin (PCT) assay aids in the diagnosis of sepsis, a serious and potentially fatal condition.

Read more

, CRP

C-reactive protein (CRP) is an infection marker used as an aid in the detection of infection and inflammatory disorders.

Read more

Pregnancy: 
ßhCG

Human chorionic gonadotropin (βhCG) is a pregnancy marker used as an aid in the early detection of pregnancy.

Read more

Ensure reliable results

Ensure accurate test results and analyser performance with the AQT90 FLEX analyser’s quality control system. It consists of three parts: built-in quality control, system quality check and liquid quality control (LQC).

 

Make decisions fast without the worry of biotin interference 

The AQT90 FLEX immunoassay analyser and assays have been tested for biotin interference. The results show no notable biotin interference in concentrations up to 2.6 mg/L (2,600 ng/mL), which is more than twice the amount recommended by the FDA [4].

Meet your regulatory needs

Meet compliance and regulatory demands with the AQT90 FLEX immunoassay analyser. The analyser includes:

  • 24/7 connectivity to HIS/LIS directly
  • Reliable results with built-in QC

You can also manage multiple AQT90 FLEX analysers with the AQURE POC IT solution. AQURE allows you to monitor analysers and manage operators and quality controls across multiple sites from one central location. With AQURE POC IT solution, you can stay ahead of compliance and accreditation needs without leaving your desk.

References

1. Nørgaard B, Mogensen CB. Blood sample tube transportation system versus point of care technology in an ED; effect on time from collection to reporting? A randomized trial. SJTREM 2012; 20, 71.
2. Larsson A et al. The state of point of care testing: a European perspective. Ups J Med Sci 2015; 120,1: 1-10.
3. St John A & Price C. Benefits of point of care testing in the emergency department. acutecaretesting.org 2018
4. FDA Safety Communication on Biotin. Nov 2017 ~ Nov 2019


MAPSSS-000812 R3

Cookies are used on this website

Use of cookies
Confirm your account with Radiometer

Please enter a valid email

CONTINUE
By submitting your e-mail you agree to the data policy notice
Radiometer is using Microsoft Azure Active Directory to authenticate customer access. If you are already registered you will be taken to Microsoft AD to sign in using your Microsoft AD credentials.
You are already registered
Radiometer is using Microsoft Azure AD to authenticate customer access. If you are already registered you will be taken to AZURE to sign in using your AZURE credentials.
Thank you

We will be sending an e-mail invitation to you shortly to sign in using Microsoft Azure AD.

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

It seems that your e-mail is not registered with us

Radiometer is using Microsoft Azure AD to authenticate customer access. If your e-mail is not registered with us please click CONTINUE and we will guide you through the sign-in process.
We have previously sent an invitation by e-mail

Please click "Get started" in the e-mail to complete the registration process

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

We were not able to process your request due to a communication error

Sorry

It seems this account has not been given access to the portal

Radiometer is using Microsoft AZURE Active Directory to authenticate users

Radiometer uses Azure AD to provide our customers and partners secure access to documents, resources, and other services on our customer portal.

If your organization is already using Azure AD you can use the same credentials to access Radiometer's customer portal.

Key benefits

       
  • Allow the use of existing Active Directory credentials
  •    
  • Single-sign on experience
  •    
  • Use same credentials to access future services    

Request access

You will receive an invitation to access our services via e-mail when your request  has been approved.

When you accept the invitation, and your organization is already using AZURE AD, you can use the same credentials to access Radiometer's customer portal. Otherwise, a one-time password will be sent via e-mail to sign in.